Search results for "Constant frequency"
showing 4 items of 4 documents
Controlling muscular force by functional electrical stimulation using intelligent PID
2015
Functional Electrical Stimulation (FES) appears as a way of extremely promising research today to solve numerous pathology connected to the deficiencies of the nervous system. It is usually used for the rehabilitation of people with neurological disorders. Generally, skeletal muscles are activated by using Constant Frequency Trains (CFTs) with a fixed amplitude and inter-pulse duration. In addition, the systems of electrical stimulation do not adapt the parameters stimulation to obtain a desired force response during the rehabilitation session. The purpose of this study is to adapt automatically the stimulation parameters to the force desired by the clinician with an intelligent PID control…
Effects of electrical stimulation pattern on quadriceps isometric force and fatigue in individuals with spinal cord injury
2015
Introduction Variable frequency trains (VFT) or train combinations have been suggested as useful strategies to offset the rapid fatigue induced by constant frequency trains (CFT) during electrical stimulation. However, most studies have been of short duration with limited functional application in those with spinal cord injury (SCI). We therefore tested force and fatigue in response to VFT, CFT, and combined patterns in strength training-like conditions (6-s contractions). Methods Ten SCI individuals underwent either CFT or VFT patterns until target torque was no longer produced and then switched immediately to the other pattern. Results Target torque was reached more times when VFT was use…
Effects of electrical stimulation pattern on quadriceps isometric force and fatigue in individuals with spinal cord injury
2015
Introduction Variable frequency trains (VFT) or train combinations have been suggested as useful strategies to offset the rapid fatigue induced by constant frequency trains (CFT) during electrical stimulation. However, most studies have been of short duration with limited functional application in those with spinal cord injury (SCI). We therefore tested force and fatigue in response to VFT, CFT, and combined patterns in strength training-like conditions (6-s contractions). Methods Ten SCI individuals underwent either CFT or VFT patterns until target torque was no longer produced and then switched immediately to the other pattern. Results Target torque was reached more times when VFT was use…
Effects of electrical stimulation pattern on quadriceps force production and fatigue
2014
Introduction: Mixed stimulation programs (MIX) that switch from constant frequency trains (CFT) to variable frequency trains have been proposed to offset the rapid fatigue induced by CFT during electrical stimulation. However, this has never been confirmed with long stimulation patterns, such as those used to evoke functional contractions. The purpose of this study was to test the hypothesis that MIX programs were less fatiguing than CFTs in strength training-like conditions (6-s contractions, 30-min). Methods: Thirteen healthy subjects underwent 2 sessions corresponding to MIX and CFT programs. Measurements included maximal voluntary isometric torque and torque evoked by each contraction. …